Source · UAE Fire and Life Safety Code of Practice, 2018, chapter 3
Escape stair risers no higher than 178 mm, and treads at least 280 mm deep.
Summarized from the source
Research
Bimiq turns the brief, site information, sources, program and constraints into structured context the design can actually use.
Research workspace
The agent reads the brief and pulls out spaces, quantities, area targets and relationships. Anything the brief leaves out is listed as an open question.
The brief
“Design a mixed-use tower on a 98 × 70 m waterfront block in Dubai: 160 apartments, about 8,000 m² of offices, a podium with a food hall, and a public garden and plaza.”
Requirements, from the brief
Open questions
Regulations, guidance and client documents stay with the requirement they support, so anyone can check where a number came from.
Source · UAE Fire and Life Safety Code of Practice, 2018, chapter 3
Escape stair risers no higher than 178 mm, and treads at least 280 mm deep.
Summarized from the source
Requirement
Escape stair risers
A citation helps you inspect the basis of a statement. Interpretation and professional review remain part of the project.
Building class
Above 90 m is super high-rise
UAE Fire and Life Safety Code
143.5 m
Refuge floors
Required in a super high-rise
UAE Fire and Life Safety Code
Levels 17, 28
Escape stair risers
178 mm maximum
UAE Fire and Life Safety Code, ch. 3
170 mm
Escape stair treads
280 mm minimum
UAE Fire and Life Safety Code, ch. 3
280 mm
Green building
Silver Sa'fa mandatory requirements
Al Sa'fat
To confirm
Code edition
2021 Dubai Building Code listed as current
Dubai Municipality
Confirm at permit
Regulatory research supports professional review. It does not replace it.
1234Bring in the boundary, access, orientation and surroundings. The site stays part of the project while the building is designed and analyzed.
Residents' entrance
Off Al Marsa Street, with the plaza and café facing the harbour.
Visitor car park
Off Al Khaleej Street, with drop-off and accessible bays.
Service and loading
From Al Mina Road, beside the ramp down to the basements.
Public garden
Lawn, play and a reflecting pool in the sunny south-west.
Spaces, quantities and area targets from the brief.
Which spaces sit close, connect or stay apart, carried into the design.
A measured boundary, an assumed storey height and a chosen refuge floor are different kinds of information. Bimiq keeps them labelled that way.
| Kind | Item | Basis |
|---|---|---|
| Fact | Block 98 × 70 m, 6,860 m² | Source: the brief |
| Fact | 160 homes, 40 / 80 / 40 | Source: the brief |
| Assumption | The site is level | Assumed, needs a survey |
| Assumption | Homes 3.2 m floor to floor, offices 4.0 m | Assumed from typical Dubai towers |
| Decision | Refuge floors at Levels 17 and 28 | 29 Sep · Above 90 m the tower is super high-rise |
| Decision | Service from Al Mina Road | Away from the residents' and office entrances |
The agent uses the project basis when it designs, checks and explains, and you can add sources at any point.
Check the escape stairs against the UAE fire code.
All 4 stair checks pass
Bring the project, and Bimiq will take it from research to a model you can keep editing.