Bimiq Logo
Bimiq
Pricing
ContactLog in

Platform

It does not just read your model. It changes it, with your permission.

An agent that drives Revit and Navisworks directly. Ask it anything about the live model, and every write it makes is previewed element by element before it runs.

It can't invent an action that isn't there.

Every question and every edit resolves to a real Revit or Navisworks operation, with its parameters checked against a strict schema before anything runs. The agent only picks from operations the model actually supports, and only fills fields it will accept.

Reads never fall back to running code. So when it tells you eight doors on Level 3 sit below the standard head height, it read them from the live model. It did not approximate.

How many doors on Level 3 sit below the standard head height?

query_elements schema checked
categoryDoors
levelLevel 3
whereHead Height below 2100 mm

Ask the live model the way you'd ask a colleague.

One question, in plain language, against the model open on your desk. The agent counts, filters and cross-checks, then answers in millimetres with a clean result, not a wall of raw properties.

Which doors on Level 3 sit below a 2100 mm head height?

Reading the door head heights on Level 3.

MarkTypeHead height
D-301Single leaf1,980 mm
D-304Double leaf2,040 mm
D-311Single leaf2,010 mm

8 of 42 doors on Level 3 sit below 2100 mm.

Interrogate
  • Which grids aren't pinned?
  • In-place families in the model
  • Walls taller than 6 m
Model QA
  • What are my worst warnings?
  • Rooms that are unplaced or unbounded
  • Views that aren't on a sheet
Quantities
  • Concrete volume by wall type
  • Total duct length
  • Floor area by department
Coordinate
  • What differs from the structural link?
  • Why is my link in the wrong place?

Nothing changes until you approve that exact change.

Ask for an edit and the agent previews it first. It shows you what it matched and the before and after for each element, and writes nothing. You approve that specific change, and only then does it commit.

Type parameters

If a change would hit every element of a type, not just your selection, it says so before it runs.

Bulk deletes

Removing more than 500 elements needs an explicit override, and it lists what Revit would take with them.

Derived values

Area, volume and wall thickness are calculated. It explains why they can't be set directly instead of failing quietly.

Preview8 matched

Set Head Height to 2100 mm on Level 3 doors

D-3011,980to2,100
D-3042,040to2,100

and 6 more

Nothing has changed yet.

Approve this changeCancel
Committed. 8 doors updated in one undo.

One conversation over the whole project.

The same agent reads and writes your Revit model and your Navisworks federation, and reads across every coordination engine, your documents and your decision log. Whatever figure it gives you, it names where the figure came from.

  • Revit

    The authoring model, read and written through the Bridge.

  • Navisworks

    The federated model and its clash tests.

  • Coordination engines

    Clash, spec, document and readiness results.

  • Documents

    Specs, consultant reports and minutes, by hybrid search.

  • Decisions and RFIs

    Past calls and the questions still open.

Compound work runs as one job.

Ask for something that takes several steps, like setting up the drawing set for a level. The agent previews the whole plan at once. Approve it once and it commits as a single undo.

Plan preview

Set up the drawing set for Level 3

  1. 1Create floor plan, Level 3
  2. 2Create sheet A103
  3. 3Place the plan on A103
  4. 4Apply view template "A1 Plan"
  5. 5Tag the doors on the view

One preview, one approval, one undo. If any step fails, the whole job rolls back.

Your next coordination cycle starts soon

Connect your model, drop in your specs, and see what Bimiq finds in the first hour.

14-day free trial. No credit card required.